Customized Emission After Treatment System for Cummins UL2.2 Urea Dosing System
Powered by Biogas SCR Dosing and Control System for Biogas Engine Genset Scaniaz DC13,250 kw Generator set
Process Flow Chart:
Detailed Information:
Biogas Engine: Scania DC13, 250 kw, Indoor Open Unit Genset
Fuel: Farm biogas.
Raw NOx emission: <500~600mg/Nm3 @5%O2
Target NOx emission: <100mg/Nm3 @5%O2
Exhaust gas Temperature: 500~550 °C, always more than 300 °C
Exhaust pipe diameter: φ200mm, insulation thickness: 40 mm.
AdBlue max dosing rate: 0.966 L/h @100% NOx reduction
Find out more other After treatment parts, please click hear.